Overview



Marketing

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Local and web-based monitoring
Status available to customers both in the data center and remotely

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Agility

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.




Specification


Technical Description: APC AP7820B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black

Certificates
Certification:
cUL, C-tick, CE, CSA, FCC 15 A, GOST, UL 60950, UL, VDE, VCCI
Compliance certificates:
RoHS

Certification
Certification:
cUL, C-tick, CE, CSA, FCC 15 A, GOST, UL 60950, UL, VDE, VCCI
Compliance certificates:
RoHS

Design
Product colour:
Black
Mounting:
Horizontal/Vertical
Rack capacity:The spase that device fill in rack.
0U/1U
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered

Features
Cable length:How long the cable is.
1.98 m
LED indicators:
Yes

Management features
Monitoring:
Current, Power, Voltage

Operational conditions
Non-operating altitude:
0 - 15000 m
Operating altitude:
0 - 3000 m
Operating relative humidity (H-H):
5 - 95%
Storage relative humidity (H-H):
5 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
-5 - 45 °C

Packaging data
Package height:The distance from the top to the bottom of the packaging.
64 mm
Package depth:The distance from the front to the back of the packaging.
337 mm
Package width:The distance from one side of the packaging to the other.
470 mm
Package weight:Weight of the packaged product.
2.91 kg

Ports & interfaces
Input connection type:The type of connection /port for the input(s) into this device e.g. USB.
IEC-320 C14
AC outlet types:The type of outlet for AC electricity.
C13 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C14 coupler
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
8 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
2300 W
Maximum total current draw per phase:
10 A
Maximum input current per phase:
15 A
Load capacity:
2300 VA
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
208-230 V
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
15 A
AC input frequency:
50 - 60 Hz
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
208-230 V

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
1.73 kg
Height:The measurement of the product from head to foot or from base to top.
44 mm
Depth:The distance from the front to the back of something.
102 mm
Width:The measurement or extent of something from side to side.
444 mm


Product details


AP7820B APC 0731304331506

APC AP7820B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black

£552.07 and In stock

SKUAP7820B

APC AP7820B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black

Quick Code: Q1655619 MPN: AP7820B

You need to be logged in to see Prices

Log In For Prices
Dont have an account? Contact Us