Overview



APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager




Specification


Technical Description: APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19

Design
Product colour:
Black
Mounting:
Vertical
Rack capacity:The spase that device fill in rack.
0U
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered, Metered-by-outlet, Switched

Features
Certification:
EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, PSE, UL, VCCI A, VDE

General
Type:Characteristics of the device.
Power Distribution Units (PDUs)

Management features
Outlet control:
Lock-out, Recycle, Turn off, Turn on
Monitoring:
Current, Power, Voltage

Operational conditions
Non-operating altitude:
0 - 15000 m
Operating altitude:
0 - 3000 m
Operating relative humidity (H-H):
5 - 95%
Storage relative humidity (H-H):
5 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
-5 - 45 °C

Packaging data
Package dimensions (WxDxH):Dimensions of the packaged product (Width x Depth x Height).
162 x 117 x 2038 mm
Package weight:Weight of the packaged product.
8.36 kg

Ports & interfaces
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
24 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
3680 W
Maximum total current draw per phase:
16 A
Maximum input current per phase:
16 A
Load capacity:
3680 VA
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
200-230 V
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
16 A
AC input frequency:
50 - 60 Hz
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
200-230 V

Technical details
Compliance certificates:
RoHS

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
6.09 kg
Dimensions (WxDxH):Dimensions of the product (Width x Depth x Height).
56 x 51 x 1829 mm


Product details


AP8659 APC 0731304299509

APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19

£1499.99 and In stock

SKUAP8659

APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A/208V, 16A/230V, (21) C13 & (3) C19

Quick Code: Q473392 MPN: AP8659

You need to be logged in to see Prices

Log In For Prices
Dont have an account? Contact Us