Overview



APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (36) C13 & (6) C19, and the cable length is 3m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.




Specification


Technical Description: APC AP8853 power distribution unit (PDU) 42 AC outlet(s) 0U Black

Certificates
Certification:
RoHS, REACH IEC 60950,VDE

Certification
Certification:
RoHS, REACH IEC 60950,VDE

Design
Product colour:
Black
Mounting:
Vertical
Rack capacity:The spase that device fill in rack.
0U
Type:Characteristics of the device.
Single-phase
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered

Features
Cable length:How long the cable is.
3 m

General
Type:Characteristics of the device.
Power Distribution Units (PDUs)

Logistics data
Total carbon footprint (kg of CO2e):
28921.23

Management features
Monitoring:
Current, Power, Voltage

Operational conditions
Operating relative humidity (H-H):
5 - 95%
Storage relative humidity (H-H):
5 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
5 - 45 °C

Ports & interfaces
Output connections:
36x IEC 320 C13 6x IEC 320 C19
Input connection type:The type of connection /port for the input(s) into this device e.g. USB.
IEC 309 32A 2P+E
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
IEC309
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
42 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
7680 W
Maximum total current draw per phase:
32 A
Maximum input current per phase:
32 A
Load capacity:
7680 VA
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
230 V
AC input frequency:
50 - 60 Hz

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
6.93 kg
Height:The measurement of the product from head to foot or from base to top.
1791 mm
Depth:The distance from the front to the back of something.
44 mm
Width:The measurement or extent of something from side to side.
56 mm


Product details


AP8853 APC 0731304277019

APC AP8853 power distribution unit (PDU) 42 AC outlet(s) 0U Black

£796.00 and In stock

SKUAP8853

APC AP8853 power distribution unit (PDU) 42 AC outlet(s) 0U Black

Quick Code: Q773442 MPN: AP8853