Overview



Description:

APC Basic Rack PDU, Input : 120, 208, 230V , Input Connection Type : IEC-320 C20 , Cord Length : 8.2 feet ( 2.5 meters ) , Output : 120, 208, 230V , Output Connections : (10)IEC 320 C13, (2)IEC 320 C19

: 19 inch Rack-Mountable, Low Cost Power Distribution, Vertical Mounting Capabilities

Includes: Cord Retention Clips, Rack Mounting Brackets, User Manual


Output Voltage(s) (main only) - 120, 208, 230 V

Maximum Total Current Draw per Phase - 16 A

Output Connections - (10)IEC 320 C13; (2)IEC 320 C19

Always on Outlets - 12
Overload Protection

Input:

Nominal input voltage - 120, 208, 230

Input frequency (Hz) - 50/60 Hz

Input Connection Type - IEC-320 C20

Cord Length 8.2 feet ( 2.5 meters )

Acceptable Input Voltage - 90-250 VAC

Maximum Line Current per phase - 16.0 A

Maximum Input Current per phase - 16.0 A

Load Capacity - 3680





Specification


Technical Description: APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black

Design
Product colour:
Black
Mounting:
Horizontal/Vertical
Rack capacity:The spase that device fill in rack.
0U/1U
Type:Characteristics of the device.
Single-phase
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Basic

Features
Cable length:How long the cable is.
2.5 m

General
Type:Characteristics of the device.
Power Distribution Units (PDUs)

Operational conditions
Operating relative humidity (H-H):
0 - 95%
Storage relative humidity (H-H):
0 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 45 °C

Ports & interfaces
I/O ports:An interface on a device to which you can connect another device.
Output Connections - (10)IEC 320 C13; (2)IEC 320 C19 Input Connection Type - IEC-320 C20
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C20 coupler
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
12 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
3680 W
Maximum input current per phase:
16 A
Load capacity:
3680 VA

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
980 g
Height:The measurement of the product from head to foot or from base to top.
44.5 mm
Depth:The distance from the front to the back of something.
57.2 mm
Width:The measurement or extent of something from side to side.
447 mm


Product details


AP9559 APC 0731304123521

APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black