Overview



Access monitoring
Detect access by unauthorized personnel via door switch.

Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.

Sleek design
Slim, modern design can be upright, flat, or wall-mounted to comfortably fit any electronics set-up and complement home décor.

Cold-start capable
Provides temporary battery power when the utility power is out.

Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Advanced Safety
Safeguard your Home UPS from overloads, excessive mains voltages, short circuits, installation mishaps and battery damage due to low voltage situations.

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Battery backup and surge protection
Outlets provide abundant runtime for network gateway equipment and other critical low-power devices, allowing for hours of internet access during a power outage.

Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes.

LED Indicators
Provide easy-to-read status of the unit and utility power conditions.

Audible alarms
Provides notification of changing utility power and UPS power conditions




Specification


Technical Description: APC BVX700LI uninterruptible power supply (UPS) Line-Interactive 0.7 kVA 360 W 4 AC outlet(s)

Battery
Cold start:
Yes
Battery recharge time:Approximate time required to recharge the battery from completely empty to completely full
8 h
Battery life (max):Maximum battery life. Mobile Mark™ (2002) is the standard often used to benchmark battery life time.
2 year(s)
Battery voltage:The voltage (V) of the battery.
12 V
Battery capacity:The amount of electric charge a battery can deliver at the rated voltage. The more electrode material contained in the cell the greater its capacity. A small cell has less capacity than a larger cell with the same chemistry, although they develop the same open-circuit voltage. Capacity is measured in units such as amp-hour (A·h).
7 Ah
Battery technology:The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)

Certificates
Certification:
CB, CE, EN/IEC 62040-1, EN/IEC 62040-2

Certification
Certification:
CB, CE, EN/IEC 62040-1, EN/IEC 62040-2

Design
International Protection (IP) code:The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes".
IP20
LED indicators:
Yes
Product colour:
Black
Form factor:The shape or design of the product.
Compact

Features
Audible alarm modes:
Alarm when on battery, Battery replacement, Low battery alarm, Overload alarm
Audible alarm(s):Alarms that make a sound when they are activated (set off).
Yes
Surge protection:
Yes
Noise level:The amplitude level of the undesired background noise, usually measured in decibels (db).
40 dB
Input power factor:
0.51
Response time:The response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
6 ms
Surge energy rating:A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
273 J
Automatic Voltage Regulation (AVR):
Yes
Output voltage regulation:
10%
Output frequency regulation:
0.5 Hz
Output frequency:
50/60 Hz
Output operation voltage (max):The maximum output voltage produced by the device.
230 V
Output operation voltage (min):The minumum voltage produced by the device during operation.
230 V
Input frequency:The frequency (Hz) which is required to power the product.
50/60 Hz
Input operation voltage (max):The maximum input voltage supported by the device.
280 V
Input operation voltage (min):The minumum voltage needed by the device during operation.
170 V
Waveform:
Sine
Output power:The power that the device can produce.
360 W
Output power capacity:The maximum power that the device can produce.
0.7 kVA
UPS topology:
Line-Interactive

General
Type:Characteristics of the device.
Uninterruptible Power Supplies (UPSs)

Logistics data
Harmonized System (HS) code:
85078000

Operational conditions
Non-operating altitude:
0 - 3000 m
Operating altitude:
0 - 3000 m
Operating relative humidity (H-H):
0 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-15 - 40 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C

Packaging content
Manual:
Yes
Cables included:
Input power cable

Packaging data
Package weight:Weight of the packaged product.
4.5 kg
Package height:The distance from the top to the bottom of the packaging.
142 mm
Package depth:The distance from the front to the back of the packaging.
346 mm
Package width:The distance from one side of the packaging to the other.
222 mm

Ports & interfaces
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
4 AC outlet(s)
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C14 coupler
AC outlet types:The type of outlet for AC electricity.
C13 coupler

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
4.5 kg
Height:The measurement of the product from head to foot or from base to top.
98 mm
Depth:The distance from the front to the back of something.
138 mm
Width:The measurement or extent of something from side to side.
31 mm


Product details


BVX700LI APC 0731304404484

APC BVX700LI uninterruptible power supply (UPS) Line-Interactive 0.7 kVA 360 W 4 AC outlet(s)

£83.99 and In stock

SKUBVX700LI

APC BVX700LI uninterruptible power supply (UPS) Line-Interactive 0.7 kVA 360 W 4 AC outlet(s)

Quick Code: Q46472 MPN: BVX700LI

You need to be logged in to see Prices

Log In For Prices
Dont have an account? Contact Us