Overview



The ATEN Professional Online UPS is an exceptional and innovative electrical apparatus that provides emergency power to a load when the input power source, or the main one, fails. The basic technology of an online UPS is the same as in a standby or line-interactive UPS, however, the ATEN Professional Online UPS provides a much greater current of AC-to-DC battery-charger / rectifier where the rectifier and inverter are designed to run continuously with improved cooling systems.

In all our years of working with computers, we’ve found the vast majority of hardware failures can be directly attributed to the stress hardware components experience during the shut-down and startup process, especially if power surges or blackouts are involved. With severe weather, the aging electrical grid, and hazards lurk inside users' own walls, their equipment is under constant attack from power problems. Even a brief loss of power, sags, or a momentary surge can ruin users' equipment and destroy irreplaceable data. Desktop computers don’t have batteries built-in like laptops do. If users are working on a desktop during a power outage, the system would come to an immediate halt. Not only would users lose their work, but the process imposes unnecessary stress on their machine.

If a UPS is present and a power loss occurs, the batteries in the UPS would keep the power steady and unchanged. The ATEN Professional Online UPS adjusts incoming AC power, provides battery backup to pass through most outages, and saves open files automatically. When power is restored, the UPS begins recharging its batteries.

The Online UPS unit continuously filters wall power through the battery system. Since the attached electronics run completely off the battery (that are always topped off by the external power supply), there is never a single millisecond of power interruption when there is power loss or voltage regulation issues. The Online UPS unit thus acts as an electronic firewall between users' devices and the outside world by stabilizing all the electricity to which users' devices are exposed.

The UPS has one USB port and one serial port that allow connection and communication between the UPS and the connected computer. Power management software installed on the connected computer(s) gives IT professionals the tools they need to easily monitor and manage their backup power. This advanced software allows users to access vital UPS battery conditions, load levels, and runtime information as well as provide unattended shut down of network computers and virtual machines connected to a battery backup during a power event.

The ATEN Professional Online UPS offers a different way to access detailed UPS settings and information with an LCD screen. The illuminated LCD screen displays input voltage, battery capacity, and more, and includes a three-button configuration interface and audible alarms for different modes of operation.

Note: When any battery pack, provided or purchased separately, is not in use, please recharge it for 4 ~ 6 hours every 3 ~ 6 months.




At-a-glance



  • ECO mode for energy saving – offers up to 97% effi ciency to cut energy usage and cost. UPS power application via static bypass timely returns to online double conversion when the need arises

  • Emergency Power Off function (EPO) – EPO connector at rear panel allows emergency UPS Power Off from a remote location

  • High power factor charger up to 1000W capacity with very low ripple current when charging battery

  • Hot swappable battery design – all potential UPS maintenance, including complete power module exchange, can be performed without powering down connected equipment As long as utility power is on, users can leave the UPS and connected equipment on while replacing the battery

  • Multi-functional LCD interface – displays immediate, detailed information on input voltage, battery capacity, power status, battery status, operating status, and assessed backup runtime, etc

  • Output voltage regulation < 1% – provides higher performance and efficiency for critical applications

  • Programmable power management outlets – users can easily and independently control load segments. During power failure, this feature enables users to extend battery time to mission-critical devices by shutting down noncritical devices

  • Provides over-voltage cut-off protection and surge immunity by MOV for full-time equipment protection

  • Smart battery charger design to optimize battery performance – adjusts charging voltage according to outside temperatures and extends the useful service life of batteries

  • SNMP + USB + RS-232 multiple communications – allows either USB or RS-232 communication ports to work with SNMP interface simultaneously

  • True double-conversion – output power factor is 1 (maxium), which means all of the power supplied is being used for productive work and makes work the most efficient




Reasons to buy


  • ECO mode for energy saving – offers up to 97% effi ciency to cut energy usage and cost. UPS power application via static bypass timely returns to online double conversion when the need arises
  • Emergency Power Off function (EPO) – EPO connector at rear panel allows emergency UPS Power Off from a remote location
  • High power factor charger up to 1000W capacity with very low ripple current when charging battery
  • Hot swappable battery design – all potential UPS maintenance, including complete power module exchange, can be performed without powering down connected equipment As long as utility power is on, users can leave the UPS and connected equipment on while replacing the battery
  • Multi-functional LCD interface – displays immediate, detailed information on input voltage, battery capacity, power status, battery status, operating status, and assessed backup runtime, etc
  • Output voltage regulation < 1% – provides higher performance and efficiency for critical applications
  • Programmable power management outlets – users can easily and independently control load segments. During power failure, this feature enables users to extend battery time to mission-critical devices by shutting down noncritical devices
  • Provides over-voltage cut-off protection and surge immunity by MOV for full-time equipment protection
  • Smart battery charger design to optimize battery performance – adjusts charging voltage according to outside temperatures and extends the useful service life of batteries
  • SNMP + USB + RS-232 multiple communications – allows either USB or RS-232 communication ports to work with SNMP interface simultaneously
  • True double-conversion – output power factor is 1 (maxium), which means all of the power supplied is being used for productive work and makes work the most efficient

Specification


Technical Description: ATEN OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA 3000 W 9 AC outlet(s)

Battery
Cold start:
Yes
Hot-swap battery:
Yes
Charging current:
8 A
Battery recharge time:Approximate time required to recharge the battery from completely empty to completely full
3 h
Number of batteries supported:The number of batteries that can be used with the product.
6
Battery voltage:The voltage (V) of the battery.
12 V
Battery capacity:The amount of electric charge a battery can deliver at the rated voltage. The more electrode material contained in the cell the greater its capacity. A small cell has less capacity than a larger cell with the same chemistry, although they develop the same open-circuit voltage. Capacity is measured in units such as amp-hour (A·h).
9 Ah
Battery technology:The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)

Certificates
Compliance certificates:
RoHS

Certification
Compliance certificates:
RoHS

Design
Rack capacity:The spase that device fill in rack.
2U
Product colour:
Black
Form factor:The shape or design of the product.
Rackmount/Tower

Features
Power protection features:Features that protect the device against power problems e.g. overload.
Over voltage
Noise level:The amplitude level of the undesired background noise, usually measured in decibels (db).
50 dB
Output voltage Total Harmonic Distortion (THD):
4%
Emergency Power Off (EPO):
Yes
ECO mode:
Yes
Crest factor:
3:1
Power factor:
1
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
14.5 A
Input frequency:The frequency (Hz) which is required to power the product.
40/70 Hz
Input operation voltage (max):The maximum input voltage supported by the device.
300 V
Input operation voltage (min):The minumum voltage needed by the device during operation.
110 V
Waveform:
Sine
Output power:The power that the device can produce.
3000 W
Output power capacity:The maximum power that the device can produce.
3 kVA
UPS topology:
Double-conversion (Online)

Logistics data
Harmonized System (HS) code:
85078000

Operational conditions
Storage relative humidity (H-H):
-20 - 50%
Operating relative humidity (H-H):
20 - 90%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-20 - 50 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C

Packaging content
Cables included:
Power load cable, USB cable
Rack mount kit:
Yes

Ports & interfaces
Emergency Power Off (EPO) connector:
Yes
Ethernet LAN (RJ-45) ports:Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
2
RS-232 ports:The number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
1
USB 2.0 ports quantity:Number of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
1
USB port type:
USB Type-B
USB port:Universal Serial Bus (USB) is an industry standard developed in the mid-1990s that defines the cables, connectors and communications protocols used in a bus for connection, communication, and power supply between computers and electronic devices. USB was designed to standardize the connection of computer peripherals (including keyboards, pointing devices, digital cameras, printers, portable media players, disk drives and network adapters) to personal computers, both to communicate and to supply electric power. It has become commonplace on other devices, such as smartphones, PDAs and video game consoles. USB has effectively replaced a variety of earlier interfaces, such as serial and parallel ports, as well as separate power chargers for portable devices.
Yes
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
9 AC outlet(s)

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
28.7 kg
Height:The measurement of the product from head to foot or from base to top.
63 mm
Depth:The distance from the front to the back of something.
88 mm
Width:The measurement or extent of something from side to side.
438 mm


Product details


OL3000HV ATEN 4719264647994

ATEN OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA 3000 W 9 AC outlet(s)

£1315.99 and In stock

SKUOL3000HV

ATEN OL3000HV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA 3000 W 9 AC outlet(s)

Quick Code: Q1642440 MPN: OL3000HV

You need to be logged in to see Prices

Log In For Prices
Dont have an account? Contact Us